RHZ1-2OL Medium Voltage Cable UNE HD 620 S3 CU(AL)/XLPE/PO
RHZ1-2OL Medium Voltage Cable UNE HD 620 S3 CU(AL)/XLPE/PO

RHZ1-2OL Medium Voltage Cable UNE HD 620 S3 CU(AL)/XLPE/PO

Medium voltage cables for distribution networks; also for connection to generation units and plant and process connection. To be laid directly in ground, outdoors, indoors and in cable ducts.
Quote Now
Share :
Application
Medium voltage cables for distribution networks; also for connection to generation units and plant and process connection. To be laid directly in ground, outdoors, indoors and in cable ducts.

Construction
● Conductor: Aluminum, class 2, circular compacted conductors 
● Conductor screen: Non-metallic,semi-conducting compound
● Insulation: Cross-Linked Polyethylene XLPE
● Insulation screen: Non-metallic,semi-conducting compound
● Metallic Screen: Copper Tape or Copper wire
● Outer sheath: Polyvinyl,PO (DMZ1,DMZ2,LSOH,LSZH),Black or Red

Chaircteritics
Good electrical and mechanical properties. Low factor dielectric loss, high insulation resistance. The PO outer sheath allows adequate resistance to UV oil and abrasion.
Different cable type require different structures and materials.

Specification
IEC 60502-2 Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1 kV(Um=1.2kV)up to 30kV(Um=36kV)-Part 2:Cables for Rated Voltages of 6kV (Um=7.2kV) and 30 kV(Um=36kV)
UNE HD 620 S3 Distribution Cables with Extruded Insulation for Rated Voltages from 3.6/6(7.2)kV to20.8/36(42)kV HD 620 S2 Distribution Cables with Extruded Insulation for Rated Voltages from 3.6/6(7.2)kV to 20.836(42)kV
ANSI/NEMA WC 74/ICEA S-93-639 5-46kV Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy ANSI/ICEA S-94-649 Concentric Neutral Cables Rated 5 Through 46 kV
High reliability
Super high pressure
Less maintenance
Power Cable RHZ1-2OL(S)
No. of Cores and Nominal Cross Section Min.Number of wires Nominal Insulation Thickness Approx. Overall Diameter Approx. Weight Max. D.C. Resistance of Conductor at 20℃
Al Al
mm² No. mm mm kg/km Ω/km
6/10kV Nominal Insulation Thickness
1X50/16 6 3.4 26.8 796 0.641
1X95/16 15 3.4 30.1 1020 0.320
1X150/25 18 3.4 32.8 1312 0.206
1X240/25 34 3.4 37.8 1774 0.125
1X400/35 53 3.4 42.7 2422 0.0778
8.7/15kV Nominal Insulation Thickness
1X50/16 6 4.5 28.8 882 0.641
1X95/16 15 4.5 32.3 1123 0.320
1X150/25 18 4.5 35.4 1457 0.206
1X240/25 34 4.5 40.0 1903 0.125
1X400/35 53 4.5 44.9 2568 0.0778
12/20kV Nominal Insulation Thickness
1X50/16 6 5.5 31.0 981 0.641
1X95/16 15 5.5 34.9 1267 0.320
1X150/25 18 5.5 38.2 1634 0.206
1X240/25 34 5.5 42.2 2042 0.125
1X400/35 53 5.5 47.1 2722 0.0778
18/30kV Nominal Insulation Thickness
1X50/16 6 8.0 36.4 1267 0.641
1X95/16 15 8.0 40.5 1606 0.320
1X150/25 18 8.0 43.2 1942 0.206
1X240/25 34 8.0 47.2 2379 0.125
1X400/35 53 8.0 52.1 3096 0.0778

Note: 1) Longitudinal water tightness of conductor and Metallic Screen (2OL)                                       
   2)
no flame propagation according to EN 60332-1-2.



For more product details, please download our PDF files.