Photovoltaic Cables  Type PV
Photovoltaic Cables  Type PV

Type PV

Medium voltage cables for distribution networks, they are suitable for laying indoor, tunnel, cables trench and underground, it is able to bear external mechanical forces, but unable to bear heavy pulling force, it widely used in transformer stations, electric power plants and industrial plants.
Quote Now
Share :
Application
Solar cables (Type PV) acc. to UL 4703, Single conductors are intended for use in interconnection wiring of grounded and ungrounded photovoltaic power systems. Heat and Moisture Resistant,concealed wiring in wet or dry locations. 

Construction
● Conductor : Bare or tinned copper,8000 service aluminum alloy or 1350 aluminum, stranded, circular or circular compressed or circular compacted conductors 
● Insulation and Jacket : XL compound,insulated and integrally or non-integrally jacketed

Characteristics
● Rated voltage 600,1000,or 2000V
● Meets cold bend and cold impact tests at -40 °C.
● Max. conductor operation temperature 90°C, 105°C,125°C,or 150°C dry and, 90°C wet
● FV-1 vertical flame rating per UL 2556.
● All aluminum AA-8000 and copper sizes are rated Direct Burial and Sunlight Resistance in all colors.
● Additional/Optional Ratings for all colors are available upon request: VW-1 per UL1581/UL 2556 Gas & Oil Res. I or II per UL 44
● Available in black, white, red, blue, green or other color

Specification
UL 44 Thermoset - Insulated Wires and Cables
UL 4703 Photovoltaic Wire
High reliability
Super high pressure
Less maintenance
Technical Parameter
No. of cores and nominal cross section Min.Number of wires Conductor 
diameter
Nominal insulation thickness Max. DC resistance of conductor
at 20℃
Current Carrying Capacity at 90℃
AWG or MCM No. mm mm Ω/km A
6 7 4.29 2.159 2.21 55
4 7 5.41 2.159 1.39 75
2 7 6.81 2.159 0.875 100
1 19 7.59 2.667 0.693 115
1/0 19 8.53 2.667 0.550 135
2/0 19 9.55 2.667 0.436 150
3/0 19 10.7 2.667 0.346 175
4/0 19 12.1 2.667 0.274 205
250 37 13.2 3.048 0.232 230
300 37 14.5 3.048 0.194 260
350 37 15.6 3.048 0.166 280
400 37 16.7 3.048 0.145 305
500 37 18.7 3.048 0.116 350
600 61 20.7 3.429 0.0967 385
750 61 23.1 3.429 0.0774 435
1000 61 26.9 3.429 0.0580 500
No. of cores and nominal cross section Min.Number of wires Conductor 
diameter
Nominal insulation thickness Max. DC resistance of conductor
at 20℃
Current Carrying Capacity at 90℃
AWG or MCM No. mm mm Ω/km A
8 7 3.61 2.159 2.14 55
6 7 4.52 2.159 1.35 75
4 7 5.72 2.159 0.848 95
2 7 7.19 2.159 0.534 130
1 19 8.18 2.667 0.423 145
1/0 19 9.19 2.667 0.335 170
2/0 19 3.61 2.667 0.266 195
3/0 19 10.3 2.667 0.211 225
4/0 19 11.6 2.667 0.167 260
250 37 13.0 3.048 0.142 290
300 37 14.2 3.048 0.118 320
350 37 15.5 3.048 0.101 350
400 37 16.8 3.048 0.0885 380
450 37 17.9 3.048 0.0787 405
500 37 19.0 3.048 0.0709 430
600 61 20.0 3.429 0.0590 475
700 61 22.0 3.429 0.0506 520
750 61 23.7 3.429 0.0472 535
1000 61 24.6 3.429 0.0354 615



For more product details, please download our PDF files.